DRY TYPE

DESCRIPTION
Dry transformers prevent fire risks and pollution produced by oil transformers, so they are used indoors in offices, hospitals, hotels, shopping malls, petrochemical industry, textile, or electronic controlled machines plants, or wherever transformers are installed close to work or leisure spaces.
ANTI-POLLUTANT

They do not pollute the environment, since there are no possibilities of spilling, they do not require any oil drainage nor expensive systems against fires. Fire resistant. They are manufactured with insulations class “B”, “F”, and “H” type “Mylar” and “Nomex”, materials that can run at 150 and 200º C temperatures each, self-extinguible, do not propagate flames, and are not explosives.

MEGGER TEST
These insultations do not absorb moisture, hence dry transformers
keep a high ohmic resistance even in an extremely humid environment, preserving their excellent dielectric features. HEAVY DUTY CYCLES It has a strong resistance to short circuits, heavy duty cycles, and regular overloads.
HEAVY DUTY CYCLES
It has a strong resistance to short circuits, heavy duty cycles, and regular overloads.
QUIET

The dry transformer runs near people, so the noise level should be under 40-60 dB according to its capacity.

LOW MAINTENANCE
Forget about the annual oil filtration or leak repairing. El
Dry transformers maintenance is minimum.

Special Building Features. CORE It is manufactured with silicon steel sheets, grain oriented, cold rolled with high magnetic permeability, M0H-M3 quality, worked to low flux densities to prevent losses and minimize excitation current.

COILS
Copper and/or aluminum magneto winding with double 220º C varnish/epoxy insulation wire and glass cover.
INSULATIONS
Type 220ºC insultations are placed between windings and layers. According to their insulation type, these materials do not absorb moisture, avoid flame propagation, and permanently guarantee an insulation resistance between windings and core.
TEMPERATURE
Windings temperature elevation.
VARNISH
A transformer assembled with coils and insulations impregnated in a 24-hour varnish coating, guaranteeing a quiet operation, improves the insulation between spirals and layers that protect the magnetic core from moisture.
CONNECTIONS
“Kulka» or «Clema» type connection terminal blocks, brass or copper sill screws according to their capacity placed on C or epoxy blocks on top of the transformer
CABINET

They can be stocked with cabinets type internal service NEMA 1, NEMA 3 rainproof or NEMA 12 dustproof manufactured with a steel sheet, finished with premier and gray color acrylic painting ANSI61, or without a cabinet, on preference.

DATA PLATE

A laminated paper plate is attached to a visible part and there is a STAINLESS-STEEL data plate for internal service on each transformer for outdoor service, clearly identifying the terminals, windings and voltages that will enable a safe connection.

TEST

Routine tests are conducted on each transformer to ensure complying with the customers’ requirements. Afterwards, a test report is submitted. Transformer turns ratio and connections polarity.

Core losses and vacuum excitation current. Cupper conductor losses and impedance percentage calculation Applied voltage to the high tension winding for 1 minute. Insulation resistance with megohmmeter.

ABSOLUTE GUARRANTY

IMEM dry transformers have a guarantee against manufacture defects and materials for a year from the shipping date. Dry transformers are ventilated with class “H” insulation prepared for running on closed environments. Due to their safe operation, especially in case of fire, they are compact designs free of maintenance. Compared to other alternatives, their advantage is that they contain a low percentage of insulating material, decreasing the toxic gas es emissions, specifically, CO.

DETAIL AND FEATURES

The client will specify the insulating materials, building details, coil impregnation, requirements testing, technical data, and additional accessories. Power: from 1 to 500KVa Source voltage: 13200 v +/- 2×2.5%, 23000 vy +/- 2×2.5%, 33000 v/y +/- 2c2.5%. Secondary voltage: 440/254, 220/127, 575/330, 480/277, 400/230, 380/220. Class H insulation: 220ºC insulation system, frequency 60 HZ, 50 HZ, etc.… Cooling: Air Natural (AN)-Forced Air (FA), connections delta/star, S/D, S/S, D/D. Standards: IRAM 2276-ANSIC57, 12.01-NOM-351. If you require other power range, voltage, or any other variants, ask a vendor.

50 years experience in transformers manufacturing.

50 years experience in transformers manufacturing.