SUBMERSIBLE TYPE

DESCRIPTION
Submersible type IMEM distribution transformers are designed to be installed in pits or vaults that from time to time can be flooded. For this reason, they must be dead front and with accessories to connect to underground distribution systems. Submersible type distribution transformers are commonly used in hospitals, historical sites or wherever the aesthetics and space are essential.
STRUCTURE
Submersible type transformers are self-cooled in insulating liquid and are classified as ONAN (Oil Natural Air Natural) They are designed to run outdoors inside a pit where there is a high level of moisture, in saline environments, and pollution caused by lead, ozone, or hydrocarbons.

They are manufactured to run at a 1,000 or 23000 m a. s. l., with a 55°C over-rising temperature, at an ambient temperature in the vault that does not exceed 50°C, and an average temperature in a 24 hour period, that does not exceed 40°C, according to the client’s specifications.

They are constructed with silicon steel grain oriented armored cores and high magnetic permeability, manufactured in unicore machines to obtain fewer vacuum losses. HV/UV coils are manufactured with low resistance electrolytic copper and/or aluminum conductors in several insulation types according to your needs.

The tanks are built with carbon steel or stainless-steel sheets, as required, and subjected to a white metal shot blasting cleaning process, an application of a rich in zinc primer, anti-rust epoxy, and a high resistance polyurethane finish. The insulating liquid is naphthenic type polychlorinated biphenyl free (NMX-J-123-ANCE).

INSTALLATION

Submersible type IMEM distribution transformers are manufactured according to the following: One-phase pole-mounted transformers for radial power supply systems connection or ring power supply systems connection. From 25 kVA to 167 kVA Three-phase pole-mounted transformers for radial power supply systems connection or ring power supply systems connection. From 25 kVA to 167 kVA

PARTS AND ACCESSORIES
  • Levering accessories (Three-phase only)
  • Sliding accessories
  • Lifting accessories
  • Tank connection to ground
  • Under voltage connection to ground
  • Under voltage bridge to ground
  • Armoring wires connectors for ground connection
    (one-phase only)
  • Armoring wires rod for ground connection
    (three-phase only)
  • Spring type under Voltage bushings
  • Pit type medium voltage bushings
  • Elbow connectors supports
  • Isolators
  • Insulation liquid level gauge (225 kVA and upper
    three-phase only)
  • Dial thermometer (225 kVA and upper three-phase only)
  • Pressure gauge supply (225 kVA and upper
    three-phase only)
  • Drain valve and sample valve
  • Top connection for press filter and leakage test
  • Overpressure relief valve
  • Branch switch
  • Drop-out fuse
  • Partial power discharge fuse
LABORATORY

We have a test laboratory that complies with the ISO-17025, where we check all the manufactured equipment, along with non standardized characteristics research and product verification.

APPLICABLE ROUTINE TESTS
  • Winding ohmic resistance
  • Insulation resistance
  • Dielectric strength of the insulating fluid
  • Applied voltage
  • Induced voltage
  • Transformation ratio
  • Phases string and polarity
  • Vacuum losses
  • Excitation current
  • Load related losses
  • Impedance voltage
  • Impenetrability
  • Coating thickness
APPLICABLE STANDARDS
  • NOM-001-SEDE-CURRENT
  • NOM-002-SEDE-ENER-2014
  • NOM-J-123-ANCE-CURRENT
  • NOM-J-287-ANCE-CURRENT
  • NOM-J-169-ANCE-CURRENT

50 years experience in transformers manufacturing.